Q
The first question is, do I really need a heated
air curtain?
A The answer is maybe not. Air doors effectively
create an efficient insulation barrier between
two environments. It's approximately 80% -
90% efficient. It does so by creating a stiff
blast of air blowing down from the unit towards
the floor. This blast of air create an invisible
barrier separating the two environments.
If you have people working near or walking
through this moving air, they may feel a breeze.
This could cause a wind chill effect, similar to
the cooling effects of a blowing fan during the
summer. Adding a heated air curtain unit will
minimize this effect and make for a comfortable
and more productive work place for your
employees and customers.
Should your facility be located in a cold weather
environment creating significant temperature
differences between the outside versus the
inside temperature, a heated unit will signi-
ficantly improve the work environment comfort
level and help maintain consistent temperature
control. In addition, it will reduce overall utility
and maintenance costs by providing a more
constant inside temperature.
TYPICAL USES
Easily mounted over entrance ways of warehouse
doors up to 16 feet high, the air curtains direct an
invisible stream of stratified heated air downward. In
addition to adding to employee and customer comfort
during cold weather they provide important energy
savings in three ways:
electric heated air curtain
1. In cold weather they reduce the load on heating
systems. By drawing warm air down to floor level
where it is needed, our air curtains utilize the 50%
of wasted heated air trapped under ceilings. Stratified
air is mixed and circulated with building heat and heat
given off by lights and machinery, etc.
ENERGY
Our air curtains conserve energy and improve comfort by
limiting the escape of internal heat, reducing cold drafts
and providing a welcoming down flow curtain of warm
air at entrance ways in industrial plants and store buildings.
The resulting mixture of warmed air disperses gently in all
directions at floor level to give uniform temperature over
a wide area from floor to ceiling with only a few degrees
difference.
2. The high velocity curtain of air deflects winds and
reduces excessive heat loss through open doorways.
3. During warm weather they can direct a stream of air
downward to help keep dust, dirt, insects and fumes from
entering through open doorways. If air conditioning exists
in the building during warm weather, the air curtains can
be used to prevent loss of conditioned air as well.
CONVENIENCE
Our air curtains allow personnel and cargo to pass freely
from one area to another while maintaining desired
temperatures.
An added safety feature is the free flow of traffic with an
unobstructed view through the opening, eliminating
doorway accidents.

Our air curtains create an invisible barrier of high velocity air
to stop cold or warm air infiltrating plant facilities and work
areas.
Stop entry of cold or warm air when doors are open.
Prevent the possibility of accidents with unobstructed
   view of passageways.
IMPORTANT: MUST BE INSTALLED ON WARM
SIDE OF DOORWAY OPENING WHEN USED FOR
TEMPERATURE CONTROL
Eliminate need for expensive plastic stripping, flapper
   doors, or canvas curtains.
Cold weather can be further deterred at door opening if
space heater in plant is directed toward intake of the air
curtain.
electric heated air curtain
SPECIFICATIONS AND FEATURES
FOR ARCHITECTS AND ENGINEERS EASY INSTALLATION
Our air curtains shall have a self-contained one piece
housing, fire retardant and corrosion proof, incorporated with
a double extended shaft motor, direct drive double width and
double inlet squirrel cage blower wheels and fan housings.
Our air curtains are bolted to wall with four fasteners and
connected to electric power source.
AIR VELOCITY CONTROL FOR VARIABLE AIR
SPEED
Shall have wedge shaped discharge nozzle containing
adjustable air deflectors with 40% sweep front to back.
Adjustable louver damper controls are provided in order to
adjust rate of air flow.
Housing shall be sufficient strength for fastening to wall on
both ends without any intermediate support.
When used over a doorway to retain warm or cold
temperature, proper velocity adjustment is imperative for
maximum efficiency. Velocity Control can reduce air velocity
up to 60% with louvers in totally closed position.
HEAVY DUTY ELECTRIC MOTOR
Continuous duty type motor with double sealed lifetime pre-
lubricated stainless steel ball bearings, resilient mounted and
protected by an automatic thermal overload switch.
Underwriters Laboratories Listed and Canadian Standards
Association Certified. Explosion proof motors available.
AIR DIRECTIONAL CONTROL
Adjustable vanes
at outlet nozzle
for directing air
to compensate
for possible draft
conditions
through doorways.
electric heated air curtain
FIRE RETARDANT AND CORROSION PROOF
Steel models are of 18 gauge paint lock metal and double
protected with gray, baked, rust preventative electrostatic
polyurethane powder coating.
NOISE LEVEL
Our air curtains operate under a low noise level in the interest
and comfort of personnel working in the immediate vicinity.

SELECTION TABLE

APPLICATIONS
BARRIER TO
INSECTS,
DUST AND FUMES
CONTAIN BLDG. AIR
HEATED OR COOLED
FREEZERS -20º
TO +25ºF
COOLERS +25º
TO +60ºF
Door widths
up to (ft)
Use this
model number
 DOOR HEIGHT UP TO (FEET)
2 1/2 28 7 7 8 10
3 36 7 7 8 10
3 1/2 42 7 7 8 10
4 48 7 7 8 10
5 60-2 7 7 8 10
6 72-2 7 7 8 10
6 1/2 78-2 7 7 8 10
7 84-2 7 7 8 10
8 96-2 or 96-3 7 7 8 10
10 120-3 9 9 9 12
12 144-3 or 144-4 7 7 8 10
4 1/2 48 HV 10 12 12 16
5 60 HV 10 10 12 14
6 72 HV-2 10 14 12 16
7 84 HV-2 10 14 12 16
8 96 HV-2 10 12 13 16
10 120 HV-2 or 120 HV-3 8 10 10 12
12 144 HV-3 10 12 14 16
14 (2) 84 HV-2 10 14 12 16
4 1/2 EP 48 16 16 16 18
5 EP 60 12 12 14 16
7 EP 84-2 16 16 16 18
8 EP 96-2 16 16 16 18
10 EP 120-2 OR EP 120-3 12 12 14 16
12 EP 144-3 16 16 16 18
14 (2) EP 84-2 16 16 16 16
16 (2) EP 96-2 16 16 16 18
18 EP 96-2 & EP 120-3 16 16 16 18
20 (2) EP 120-2 12 12 14 16
20 (2) EP 120-3 16 16 16 18

Standard Features:
1/2 HP Direct Drive
15 3/8" Profile Metal Design
Easy Install
Motor Fan Assembly Gray Powder Coating
PRICING AND SPECIFICATIONS (ELECTRIC HEATED MODELS)
Full freight allowed. Prices included delivery to any destination within the Continental United States or to Port of
Embarkation for Overseas shipments.
IMMEDIATE FREE DELIVERY MADE WITH PRIDE IN THE USA
ELECTRIC HEATED STANDARD SERIES PRICES
Model No. Width
(in)
Max.
Velocity
(fpm)
Air
Volume
(cfm)
Motor(s)
@hp
Electric kW
208-240/1**
Electric kW
208-230/460/3**
Temp
Rise F
Weight
(lbs)
Price
STD 36-1E* 36 3400 2550 1@1/2hp 6 12 15 70 $1,721
STD 42-1E* 42 2925 2550 1@1/2hp 6 12 15 75 $1,782
STD 48-1E* 48 2550 2550 1@1/2hp 6 12 15 80 $1,804
STD 64-2E* 64 3825 5100 2@1/2hp 12 24 15 155 $2,897
STD 72-2E* 72 3400 5100 2@1/2hp 12 24 15 160 $3,208
STD 78-2E* 78 3200 5100 2@1/2hp 12 24 15 160 $3,280
STD 84-2E* 84 2925 5100 2@1/2hp 12 24 15 165 $3,336
STD 96-2E* 96 2250 5100 2@1/2hp 12 24 15 180 $3,408
STD 96-3E* 96 3825 7650 3@1/2hp CF 36 15 215 $4,268
STD 108-3E* 108 3400 7650 3@1/2hp CF 36 15 225 $4,340
STD 120-3E* 120 3060 7650 3@1/2hp CF 36 15 240 $4,412
STD 144-3E* 144 2550 7650 3@1/2hp CF 36 15 255 $4,484
*Add Code for required voltage from chart above
** Additional kW configurations available
Optional Color Available - Standard Production Color is Battleship Gray
Obsidian Black - $20.00 per linear foot (indicate OB after voltage code)
Pearl White - $20.00 per linear foot (indicate PW after voltage code)
Titanium Silver - $20.00 per linear foot (indicate TS after voltage code)
Spartan Bronze - $20.00 per linear foot (indicate SB after voltage code)
Stainless Steel - $167.00 per linear foot (indicate SS after voltage code)

Full freight allowed. Prices included delivery to any destination within the Continental United States or to Port of
Embarkation for Overseas shipments.
IMMEDIATE FREE DELIVERY MADE WITH PRIDE IN THE USA
Standard Features:
1 HP Direct Drive Easy Install
18" Profile Metal Design Gray Powder Coating
*Add Code for required voltage from chart below
** Additional kW configurations available
ELECTRIC HEATED HIGH VELOCITY MODELS PRICES
Model No. Electric kW 208-230/460/3** Weight (lbs) Price
HV 48-1E* 12 145 $2,109
HV 60-1E* 12 155 $2,153
HV 72-2E* 24 315 $4,007
HV 84-2E* 24 335 $4,068
HV 96-2E* 24 340 $4,118
HV 108-2E* 24 350 $4,185
HV 108-3E* 36 425 $5,489
HV 120-2E* 24 365 $4,207
HV 120-3E* 36 440 $5,550
HV 144-3E* 36 465 $5,655


Standard Features:
3 HP Direct Drive Easy Install
18" Profile Metal Design Gray Powder Coating
*Add Code for required voltage from chart below
** Additional kW configurations available
ELECTRIC HEATED EXTRA POWER MODELS PRICES
Model No. Electric kW 208-230/460/3** Weight (lbs) Price
EP 48-1E* 12 145 $2,298
EP 60-1E* 12 155 $2,342
EP 84-2E* 24 335 $4,368
EP 96-2E* 24 340 $4,434
EP 108-2E* 24 350 $4,468
EP 108-3E* 36 425 $5,955
EP 120-2E* 24 365 $4,496
EP 120-3E* 36 440 $6,022
EP 144-3E* 36 465 $6,127
Optional Color Available - Standard Production Color is Battleship Gray
Obsidian Black - $20.00 per linear foot (indicate OB after voltage code)
Pearl White - $20.00 per linear foot (indicate PW after voltage code)
Titanium Silver - $20.00 per linear foot (indicate TS after voltage code)
Spartan Bronze - $20.00 per linear foot (indicate SB after voltage code)
Stainless Steel - $167.00 per linear foot (indicate SS after voltage code)

ACCESSORIES - Electric Heated
Unit includes a motor control panel on righthand side of unit and a remote 24v thermostat with heat/off/fan only switch
LEVEL 1 CONTROL PACKAGE - Low Traffic Doors
LOW VOLTAGE (24v) Control
Part No. Package Price
99-014 Door Limit Switch - Both Plunger & Roller all-in-one 20 amps, up to 250v, up 1 HP $66.60
90-070 Dry Bulb Thermostat-Factory Mounted $277.50
99-081 Industrial Magnetic Reed Switch (only)
Used in conjunction with control panel
$33.30
99-017 Floor Mounted Magnetic Reed Switch (only)
Used in conjunction with control panel
$77.70
LEVEL 2 CONTROL PACKAGE - High Traffic Doors (Recommended)
LINE VOLTAGE CONTROL
Part No. Package Price
J0034 Door Limit Switch with Adjustable Time Delay (1 sec - 17 min) $222.00
24 VOLT CONTROL
Part No. Package Price
J0040 Industrial Magnetic Reed switch with Adjustable Time Delay (1 sec - 17min) $222.00
J0039 Floor Mounted Magnetic Reed Switch with Adjustable Time Delay (1 sec - 17 min) $222.00
OPTIONAL CONTROLS - Can be paired with any control package
Part No. Package Price
MSLAV Master Slave Control with Single Thermostat.
Used to control multiple units side by side
$99.90/
Slave
HL2SPD Two speed Motor with Hi/Lo switch located on control panel
NOTE: If 460v power is specified a separate 115v or 208/230v single
phase motor service is required
$155.40
MOUNTING BRACKETS
Part No. Mounting Bracket Price
J0016 5" Side Extension Plates - to clear track on either end $77.70/set
J0017 7" Side Extension Plates - to clear track on either end $77.70/set
J0018 9" Side Extension Plates - to clear track on either end $77.70/set
J0004 2 1/2" Clearance Mounting Bracket - to clear wall obstructions $55.50/set
J0005 4" Clearance Mounting Bracket - to clear wall obstructions $77.70/set
J0006 7" Clearance Mounting Bracket - to clear wall obstructions $77.70/set
J0007 10" Clearance Mounting Bracket - to clear wall obstructions $77.70/set
J0008G 10" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $155.40/set
J0009G 16" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $155.40/set
J0010G 19" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $177.60/set
J0011G 23" Clearance Extended Wall Mouting Bracket - drum style roll-up doors $177.60/set
*Consult us for vertical mount
FILTERS
Part No. Filters Price
FIL-(size) Aluminum Mesh (1/4") - indicate size in inches $8.88/ft.

1/2 HP STANDARD HEATED MODELS DRAWING
electric heated air curtain NOTES:
1. This product is designed to comply with the National
    Electric Code (NEC) and is ETL certified.
2. 7/16" mounting holes (4) provided, (2) on each end.
3. All units have a self contained one piece cabinet, fire
    retardant and corrosion proof paint lock metal,
    double protected with baked on gray color rust pre-
    ventative electrostatic polyurethane powder coating.
4. Cabinet has sufficient strength for suspension from
    both ends without intermediate support.
5. Allow a minimum of 17" clearance for access to
    control panel door for installation and maintenance.
6. Control panel is prewired and premounted or right
    hand side of cabinet, specify for alternate location.
7. Unit is to be installed such that air flow is unob-
    structed. Air discharge nozzle containing adjustable
    air directional vanes with 40° sweep front to back.
8. Wall mounted 24 volt thermostat with remote"heat/
    off/fan" switch shipped loose and field installed.
    Terminal block provided inside panel.
9. Branch circuit protected as per NEC by others.
10. Optional door limit switch is field installed.
      Switch to be mounted such that the air curtain
      turns on as door begins to open. A time delay is
      highly recommended with the optional door limit
      switch.
-2 &-3 designates the number of motors. *NOTE: Louver assembly size and number varies with length.
electric heated air curtain
Model
No.
Mounting Centers
A
Length
B
Depth
C
Height
D
E36 35 1/8" 36" 11 1/4" 15 3/8"
E38 37 1/8" 38" 11 1/4" 15 3/8"
E42 41 1/8" 42" 11 1/4" 15 3/8"
E48 47 1/8" 48" 11 1/4" 15 3/8"
E60 59 1/8" 60" 11 1/4" 15 3/8"
E64-2 63 1/8" 64" 11 1/4" 15 3/8"
E72-2 71 1/8" 72" 11 1/4" 15 3/8"
E78-2 77 1/8" 78" 11 1/4" 15 3/8"
E84-2 83 1/8" 84" 11 1/4" 15 3/8"
E96-2 95 1/8" 96" 11 1/4" 15 3/8"
E96-3 95 1/8" 96" 11 1/4" 15 3/8"
E108-3 107 1/8" 108" 11 1/4" 15 3/8"
E120-3 119 1/8" 120" 11 1/4" 15 3/8"
E144-3 143 1/8" 144" 11 1/4" 15 3/8"
TYPICAL INSTALLATION
1. Supply is connected to the line terminal block in the panel. (8)
2. Thermostat is mounted in a convenient location and connected
    to the labeled terminal block in the panel.
3. The air curtains may run continuously or be controlled by a
    door microswitch connected to labeled terminal block in the
    panel.
4. Motor must run in specified direction of rotation.

HIGH VELOCITY AND EXTRA POWER ELECTRIC HEATED MODELS DRAWING
electric heated air curtain NOTES:
1. This product is designed to comply with the National
    Electric Code (NEC).
2. 7/16" mounting holes (4) provided, (2) on each end.
3. All units have a self contained one piece cabinet, fire
    retardant and corrosion proof paint lock metal,
    double protected with baked on gray color rust pre-
    ventative electrostatic polyurethane powder coating.
4. Cabinet has sufficient strength for suspension from
    both ends without intermediate support.
5. Allow a minimum of 17" clearance for access to
    control panel door for installation and maintenance.
6. Control panel is prewired and premounted or right
    hand side of cabinet, specify for alternate location.
7. Unit is to be installed such that air flow is unob-
    structed. Air discharge nozzle containing adjustable
    air directional vanes with 40° sweep front to back.
8. Wall mounted 24 volt thermostat with remote"heat/
    off/fan" switch shipped loose and field installed.
    Terminal block provided inside panel.
9. Branch circuit protected as per NEC by others.
10. Optional microswitch is field installed. Terminal
      block provided inside panel. Switch to be mounted
      such that the air curtain turns on as door begins to
      open. A time delay is highly recommended with
      the optional microswitch.
-2 &-3 designates the number of motors. *NOTE: Louver assembly size and number
varies with length.
Model
No.
Number of Motors Mounting Centers
A
Overall Length
B
E48HV 1 47 1/8" 48"
E60HV 1 59 1/8" 60"
E72HV-2 2 71 1/8" 72"
E84HV-2 2 83 1/8" 84"
E96HV-2 2 95 1/8" 96"
E120HV-2 2 119 1/8" 120"
E120HV-3 3 119 1/8" 120"
E144HV-3 3 143 1/8" 144"
EEP48 1 47 1/8" 48"
EEP60 1 59 1/8" 60"
EEP72-2 2 71 1/8" 72"
EEP84-2 2 83 1/8" 84"
EEP96-2 2 95 1/8" 96"
EEP120-2 2 119 1/8" 120"
EEP120-3 3 119 1/8" 120"
EEP144-3 3 143 1/8" 144"
electric heated air curtain
TYPICAL INSTALLATION
1. Supply is connected to the line terminal block in the panel. (9)
2. Thermostat is mounted in a convenient location and connected
    to the labeled terminal block in the panel.
3. The air curtains may run continuously or be controlled by a
    door microswitch connected to labeled terminal block in the
    panel.
4. Motor must run in specified direction of rotation.

INSTALLATION INSTRUCTIONS FOR ELECTRIC HEATED
HIGH VELOCITY AND EXTRA POWER MODELS
PRELIMINARY
TO INSTALL HOUSING AND
MOTOR/FAN ASSEMBLY

1. Before removing the unit from the carton, unscrew the plastic
    nuts and remove the adjustable velocity control louver.
2. Remove the Motor/Fan Assembly from its carton. Industrial
    models have the motor/fan assembly(s) shipped separately.
    Be careful not to touch the dynamically balanced wheels or
    damage the electric heating elements when removing the motor/
    fan assembly from the box.
3. Remove the housing from the carton.
   WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
    SHOCK OR INJURY TO PERSONS, OBSERVE THE
    FOLLOWING:

          A. Installation work or electrical wiring must be done by
               qualified person(s) in accordance with all applicable codes
                and standard, including fire-rated construction.
          B. The combustion airflow needed for safe operation of fuel
               burning equipment in the area may be affected by the
               unit's operation. Follow the heating equipment manu-
               facturer's guideline and safety standards, such as those
               published by the National Fire Protection Association
               (NFPA), the American Society of Heating, Refrigeration
               and Air Conditioning Engineers (ASHRAE) and local code
               authorities.
          C. When cutting or drilling into a wall or ceiling, be careful
               not to damage electrical wiring and other hidden utilities.

1. Measure the housing, and then center it on the wall over the
    doorway opening. See Table I for the minimum clearance required
    on the panel side of the unit for access and service.
2. Spot holes through 7/16" mounting holes. (2) on each end of the
    housing. If necessary, drill extra holes in the back of the housing
    to align with stud spacing. (See Figure 1)
3. Mount the unit with the discharge nozzle 1" above the door
    opening. If the unit is mounted higher, move it 3/8" away from
    the wall for every 1" it is moved up above the door. Any void
    between wall and unit must be sealed for optimum performance.
    Threaded rods may be used for overhead installation.
4. Use all four mounting holes when installing the housing.
5. When mounting multiple units side by side, allow no more than
    6" between the units. Master/Slave configuration required to
    allow the units to operate simultaneously. (Single T'stat Control)
    (see figure 2)
6. Replace Motor/Fan Assembly(s) in the housing and secure
    with wingnuts. Connect all motor(s) and electric heater(s)
    connections.
7. Replace the intake louver or inlet screen and fasten with the
    hex nuts.
8. Connect panel to proper voltage. Check the motor rotation.
    (See Figure 1)

FIGURE 1
ADJUSTMENTS
electric heated air curtain
1. Pull air directional vanes in air discharge nozzle to proper
    position with air flow slated slightly outward around 15°.
2. Set air velocity control louvers so that the air stream just
    reaches the floor to prevent turbulent mixing of inside and
    outside air.
3. The unit is to be installed such that the airflow is unobstructed.
4. The thermostat should be mounted such that it senses the room
    temperature. Do not mount thermostat on a cold wall, below a
    discharge grill or in direct sunlight. The high limit switches may
    trip, shutting off the heat, if improperly installed.
NOTE: MODEL NUMBER DESIGNATES THE LENGTH OF THE
              UNIT IN INCHES, WHICH IS DENOTED AS "L". ALL
              DIMENSIONS ARE IN INCHES.
TABLE 1
Model
No.
Motor
HP
Number
of
Motors
Mounting Centers
A
Min. Panel Clearance Req'd (B)
E48HV 1 1 47 1/8" 17"
E60HV 1 1 59 1/8" 17"
E72HV-2 1 2 71 1/8" 21"
E84HV-2 1 2 83 1/8" 21"
E96HV-2 1 2 95 1/8" 21"
E120HV-2 1 2 119 1/8" 21"
E120HV-3 1 3 119 1/8" 21"
E144HV-3 1 3 143 1/8" 21"
EEP48 3 1 47 1/8" 17"
EEP60 3 1 59 1/8" 17"
EEP72-2 3 2 71 1/8" 21"
EEP84-2 3 2 83 1/8" 21"
EEP96-2 3 2 95 1/8" 21"
EEP120-2 3 2 119 1/8" 21"
EEP120-3 3 3 119 1/8" 21"
EEP144-3 3 3 143 1/8" 21"
FIGURE 2
electric heated air curtain
CONTROL PANEL INSTALLATION
A. Connect supply voltage from power panel to control panel. Circuit protection as per NEC by others.
B. Connect motor and heater leads to leads from the control panel and connect thermostat to terminals in panel per print.
C. Connect wires from microswitch to terminals in control panel per print.
D. Check rotation of blower wheels. Switch leads if necessary to correct.
E. The door microswitch has normally closed contacts. The contacts open when the door shuts depressing the plunger, turning the Air
    Curtain off.

TYPICAL INSTALLATION OF METAL AIR CURTAINS
FOR DRUM TYPE ROLL-UP DOORS
electric heated air curtain

TYPICAL INSTALLATION FOR VERTICAL LIFT TRACK DOORS
electric heated air curtain

TYPICAL INSTALLATION FOR OVERHEAD MOUNTING
electric heated air curtain
Electric Heated Air Curtains, Air Curtain, Air Curtain Door, Air Curtain Heater, Air Curtains, Air Doors, Door Air Curtains, Heat
Curtains, Mars Air Curtain, Mars Air Door, Warm Air Curtains, and Insect Barrier from your source for material handling equipment.

Back to Product Page

HOME / INDEX / ORDER / SEARCH / QUOTE / INFO / ABOUT US