LKG LK Goodwin Co. Material Handling Equipment Toll Free: 1-800-343-2478
HOME ORDER SEARCH QUOTE CONTACT US ABOUT US MY ACCOUNT SHOPPING CART
 
Product Index
 
Back to Product Page

COMMERICAL HIGH PERFORMANCE 10
AIR CURTAINS ELECTRIC HEATED

Meets 2015 IECC Building Code which added AMCA Certified air curtains as an exception to a vestibule.
Commercial High Performance 10 Series (CHD10) air curtains
(a.k.a. air doors) are designed to be competitively priced for use
at customer entry and service entry doors. They are suitable for
opening heights up to 10 ft for environmental separation and up
to 8 ft for insect control.
Ideal Applications:
Service / Employee Doors
Main Entrances
Conveyors
Shipping & Receiving
Tamper Resistant Correctional Package Available
Simple design, high performance, white or black
powder-coated exterior.
Custom colors or stainless steel
(Grade 304 or better) available (call us).
Air curtains provide environmental separation at openings by reducing the infiltration of unconditioned air, fumes,
dust, and humidity. At exterior openings, they can resist winds up to 10 MPH (16 KPH) and are generally mounted
inside the building. During cold seasons warm air that has risen towards ceiling is recirculated; they can also be used
at interior openings such as doors to coolers or clean rooms. Optimum protection is provided when units are mounted
flush to the wall and as close to top of door opening as possible. To ensure peak performance keep air stream free of
obstructions. Air curtains may not be fully effective where negative air pressure exists on one side of door; contact us
for additional information
Series CHD10 model air curtains have 1/2 HP motors. They can be wall mounted or suspended from the ceiling.
Electric heated units shall be installed indoors only and require - a minimum clearance of at least 6 ft between the
bottom of the unit and the floor, a minimum of 8 in between the top and ceiling and 1 in between the sides and
any combustible material.
Standard Construction
• 14” high x 15” deep
• ½ hp three-speed motor(s)
• Factory installed fan speed switch
• White or black aluminum exterior cover
• Wall and top mounting
Installation & Mounting
Simple to install, operate & maintain
• Single lengths up to 10’
• No Assembly Required
• 1/4” keyhole slots for wall mounting
• 5/16” threaded inserts for top mounting
Optional: Wall mounting plate
Control Package:
• Deluxe



COMMERCIAL HIGH PERFORMANCE 10 Electric Heated Air Curtain Data Sheet
MODEL 
Nozzle
Width
(in) 
Max
Vel. at
Nozzle
(fpm) 
Avg.
Outlet
Vel.
(fpm) 
Air
Volume
(cfm) 
Outlet
Vel.
Uniformity 
Power
Rating
(kW) 
Motor(s)
@ hp 
Max
Electric
Capacity
(kW) 
Heater
Output
(MBH) 
Air
Temp.
Rise
(°F) 
Net
Wt.
(lbs) 
CHD10-1036E 
36
3,284
1,928
1,687
70%
0.73
1 @ 1/2 
14
47.8
26° 
52
CHD10-1042E 
42
3,592
1,727
1,763
50%
0.77
1 @ 1/2 
14
47.8
25° 
55
CHD10-1048E 
48
3,614
1,473
1,718
38%
0.69
1 @ 1/2 
14
47.8
26° 
56
CHD10-1060E 
60
3,319
1,119
1,632
45%
0.66
1 @ 1/2 
14
47.8
27° 
63
CHD10-2060E 
60
3,711
1,788
2,607
59%
1.22
2 @ 1/2 
21
71.7
25° 
96
CHD10-2072E 
72
3,284
1,928
3,374
70%
1.45
2 @ 1/2 
28
95.6
26° 
104
CHD10-2084E 
87
3,592
1,667
3,526
50%
1.54
2 @ 1/2 
28
95.6
25° 
110
CHD10-2096E 
99
3,614
1,428
3,436
38%
1.38
2 @ 1/2 
28
95.6
26° 
112
CHD10-3096E 
99
3,284
1,785
4,294
59%
1.95
3 @ 1/2 
35
119.5
26° 
148
CHD10-2108E 
111
3,319
1,242
3,350
38%
1.35
2 @ 1/2 
28
95.6
26° 
119
CHD10-3108E 
111
3,284
1,876
5,061
70%
2.18
3 @ 1/2 
42
143.3
26° 
156
CHD10-2120E 
116.25
3,319
1,155
3,264
45%
1.32
2 @ 1/2 
28
95.6
27° 
126
CHD10-3120E 
116.25
3,284
1,818
5,137
50%
2.22
3 @ 1/2 
42
143.3
26° 
159
1. NOTE: Operation at 50 Hz will generate approximately a 17% reduction in air performance.
2. Performance data based on AMCA licensed data from unheated units.
We do not recommend CHD10-1060E, CHD10-2108E & CHD10-2120E, exists only as an equivalent to competitors’ models.

Electric Heated Air Curtain Electrical Performance Sheet
208/3/60 (voltage code X)
240/3/60 (voltage code Y)
MOTOR AMP DRAW = 3.5 ea.
MOTOR AMP DRAW = 3.5 ea.
MODEL 
kW
(code)
Temp
Rise
ºF
#
CKTS
AMPS PER
CIRCUIT
(including motor)
BREAKER
RATING PER
CIRCUIT
#
CKTS
AMPS PER
CIRCUIT
(including motor)
BREAKER
RATING PER
CIRCUIT
CHD10-1036E
CHD10-1042E
CHD10-1048E
CHD10-1060E
14
25
1
42.4
60
1
37.2
50
10
18
1
31.3
40
1
27.6
35
8
14
1
25.7
35
1
22.7
30
6
11
1
20.2
30
1
17.9
25
CHD10-2060E
21
25
2
26.4/38.9
35/50
2
23.8/33.7
30/45
15
18
1
48.6
60
1
43.1
60
12
14
1
40.3
50
1
35.9
45
9
11
1
32
40
1
28.7
35
CHD10-2072E
CHD10-2084E
CHD10-2096
CHD10-2108E
CHD10-2120E
28
25
2
45.9/38.9
60/50
2
40.7/33.7
50/45
20
18
2
34.8/27.8
45/35
2
31.1/24.1
40/35
16
14
2
29.2/22.2
40/30
1
45.5
60
12
11
1
40.3
50
1
35.9
45
CHD10-3096E 
35
25
3
29.9/38.9/38.9
40/50/50
3
27.3/33.7/33.7
35/45/45
25
18
2
38.3/41.6
50/60
2
34.6/36.1
45/50
20
14
2
32.7/33.3
4045
2
29.7/28.9
40/40
15
11
2
27.2/25.0
35/35
2
24.9/21.7
30/30
CHD10-3108E
CHD10-3120E
42
25
3
49.4/38.9/38.9
60/50/50
3
44.2/33.7/33.7
60/45/45
30
18
3
38.3/27.8/27.8
50/35/35
2
34.6/48.1
45/60
24
14
2
32.7/44.4
40/60
2
29.7/38.5
40/50
18
11
2
27.2/33.3
35/45
2
24.9/28.9
30/40
480/3/60 (voltage code Z)
600/3/60 (voltage code Q)
MOTOR AMP DRAW = 1.4 ea.
MOTOR AMP DRAW = 1.0 ea.
MODEL 
kW
(code)
Temp
Rise
ºF
#
CKTS
AMPS PER
CIRCUIT
(including motor)
BREAKER
RATING PER
CIRCUIT
#
CKTS
AMPS PER
CIRCUIT
(including motor)
BREAKER
RATING PER
CIRCUIT
CHD10-1036E
CHD10-1042E
CHD10-1048E
CHD10-1060E
14
25
1
18.2
25
1
14.5
20
10
18
1
13.4
20
1
10.6
15
8
14
1
11
15
1
8.7
15
6
11
1
8.6
15
1
6.8
15
CHD10-2060E
21
25
1
28.1
35
1
22.2
30
15
18
1
20.8
30
1
16.4
25
12
14
1
17.2
25
1
13.5
20
9
11
1
13.6
20
1
10.7
15
CHD10-2072E
CHD10-2084E
CHD10-2096
CHD10-2108E
CHD10-2120E
28
25
1
36.5
50
1
28.9
40
20
18
1
26.9
35
1
21.2
30
16
14
1
22
30
1
17.4
25
12
11
1
17.2
25
1
13.5
20
CHD10-3096E 
35
25
1
46.3
60
1
36.7
50
25
18
1
34.3
45
1
27.1
35
20
14
1
28.3
35
1
22.2
30
15
11
1
22.2
30
1
17.4
25
CHD10-3108E
CHD10-3120E
42
25
2
21.0/33.7
30/45
1
43.4
60
30
18
1
40.3
50
1
31.9
40
24
14
1
33.1
45
1
26.1
35
18
11
1
25.9
35
1
20.3
25

CHD10 ELECTRIC HEATED
NOTES:
1. Air curtain must be installed so air
    stream is not obstructed when
    deflected 20° to either side of C.
2. Electrical connections to be flexible.
3. Field verify dimensions.
4. Anchors to supporting structure
   by others.
5. Adequacy of supporting structure
    is to be verified by a professional
    structural engineer.
6. Letter "E" in model number designates
    electric heated unit.
7. Dimensions in inches [centimeters].


Order Online, by Phone, or by E-Mail

~ Add items to your online shopping cart ~
Click a Price of the item you wish to purchase.

MODEL # 
PRICING
Std. Elect.
kW
ShipWt.
(lbs.)
208-240V 3PH ¹
480-600V 3PH ³
CHD10-1036E 
14
66
CHD10-1042E 
14
70
CHD10-1048E 
14
71
CHD10-1060E 
14
78
CHD10-2060E 
21
116
CHD10-2072E 
28
124
CHD10-2084E 
28
140
CHD10-2096E 
28
174
CHD10-3096E 
35
210
CHD10-2108E 
28
200
CHD10-3108E 
42
218
CHD10-2120E 
28
207
CHD10-3120E 
42
221
³ Control Voltage: 24V
¹ Control Voltage: 208V 240V (control package required for 24V control)

Order Online, by Phone, or by E-Mail

~ Add items to your online shopping cart ~
Click the Model No. of the item you wish to purchase.

OPTIONS
Deluxe Control Package (includes time delay relay, 24 volt control transfomer, and magentic reed door switch)
Model No.
Description
Price
NEMA 1 Magnetic Reed 120-240V, White
$398
*NEMA 1 Magnetic Reed 480V, White
$299
*Transformer included in air curtain price.
Model No.
Description
Price
Thermostat
$77
High Performance Electric Heated Air Curtains, High Performance Air Curtains, Commercial Air Curtains, Commercial Air Door, Electric Heated Air Curtains, and Insect Barrier from your source for material handling equipment.

Back to Product Page

HOME / ORDER / SEARCH / QUOTE / CONTACT US / ABOUT US / MY ACCOUNT/ SHOPPING CART