LKG LK Goodwin Co. Material Handling Equipment Toll Free: 1-800-343-2478
HOME ORDER SEARCH QUOTE CONTACT US ABOUT US MY ACCOUNT SHOPPING CART
 
Product Index
 
Back to Product Page

DOUBLE AUTO ATTENDANT WASTE CONTAINER


Order Online, by Phone, or by E-Mail

~ Add items to your online shopping cart ~
Click the Model No. of the item you wish to purchase.


Double Auto Attendant® cast aluminum lid with security
cable and 20 gallon liner standard. ADA compliant design.

Size:
21" x 38" x 33 3/4"
Unit Weight:
660 lbs
Unit Capacity: 20 Gallons
Reinforcing: 1/4" Dia. steel rebar
Material: Reinforced concrete, Aluminum
Logo Options: Inkjet or cast in place
Model: TF1242
Price: $1,120.00
(2) Wash & Towel Holder Included

AVAILABLE COLORS



Concrete Specification
1.1 SUMMARY
      A. Section includes: Furnish Precast Concrete indicated on drawing or specified herein.

1.2 REFERENCES

      A. American Society for Testing & Material
           1. ASTM C33 2. ASTM C150 3.ASTM C31

1.5 SUBMITTALS

     A. Submit Product data,shop drawings and samples.
          1. Product Data: Manufacturer’s specifications and technical data edited specifically for proposed system,
              including the following specific Information:
                  a: Detailed specification of construction fabrication.
                  b: Manufacture’s installation instructions
                  c: Maintenance literature
                  d: Product warranty
          2. Shop Drawings: Indicate pertinent dimensions, general construction, component connections anchoring
              methods, hardware and installation procedures.
          3. Samples as requested by Architect.

1.6 QUALITY ASSURANCE
      A. Qualifications of Manufacture: Manufacturer to be prequalified by specifier prior to bidding. Failure to comply
           will result in disqualification of bid. Manufacturer to have at least five years experience in the manufacture of
           precast concrete field proven for at least five years.

1.10 WARRANTY
        Manufacturer shall submit a written warranty for precast products for the period of two years upon acceptance.

2.1 MANUFACTURERS
      A. Clarification Note: Drawings and installation specification are based on manufactures proprietary literature
           from us. Other manufacturers shall comply with minimum levels of material and detailing indicated on
          drawings of specified herein.
      B. All Precast products for this project shall be of one manufacturer.

2.2 MATERIALS
      A. Portland cement: ASTM C150 specifications for Portland cement.
      B. Aggregates: All aggregates to meet ASTM C33 specifications, to be cleaned of foreign matter and properly
      graded to size.
      C. Coloring: Pigments used shall be inorganic, resistant to alkalinity and used as per manufacturers
      recommendations.

TECHNICAL INFORMATION - POWDURA® Epoxy Powder Coating

PRODUCT DESCRIPTION
EAS6-00025
ZINC RICH PRIMER

POWDURA® Epoxy Powder Coating is recommended for a broad range of interior functional and
decorative applications.

APPLICATION
Cure Schedule: 10 min @ 205°C (401°F)
Film Thickness Range: 1.5-1.8 mils

ATTRIBUTES
Specific Gravity: 2.83 +/-0.05
Coverage at 1.0 mil: 67.8 sq.ft/lb
60 Gloss: Visual
Adhesion: No Failure with 1/16in. squares(5B) (ASTM D-3359)
Flexibility: Pass 1/8" Mandrel Bend (ASTM D-522)
Pencil Hardness:
H-2H (ASTM D-3363)
Impact Resistance(dir/rev): 160/160 (ASTM D-2794)

Other Notes

SaltSpray Performance: When top coated with TGIC polyesters,urethanes and fluoroploymers, testing showed
4-5 mm undercut at 5000 hours on Bonderite 1000

Storage:
POWDURA® Powder Coatings should be kept in a dry and cool area at temperatures below 80°F (26.7° C).
Shelf life is approximately 12 months.
When not in use, store powder in sealed containers: fine powders are hygroscopic.

Substrate Preparation
General: Substrate should be free of grease, oil, dirt, fingerprints, drawing compounds, any contamination, and
surface preparation treatments to ensure optimum adhesion and coating performance properties. The use of a
chemical conversion coating prior to the application of a powder coating is strongly recommended. Consult Metal
Preparation Brochure CC-T1 for additional details.

Aluminum: A minimum of a 5-stage chrome phosphate metal treatment, or equivalent, is required for good adhesion
and optimum coating performance properties.

Testing:
Due to the wide variety of substrates, surface preparation methods, application methods, and environments,
the customer should test the complete system for adhesion and compatibility prior to full-scale application.
The properties listed are typical and should not be construed as the actual specification.

Product Limitations:
Contact your Sherwin-Williams Representative where use of this product at higher than recommended film
thickness may be required.

APPLICATION:
Powder coatings must be applied using suitable electrostatic equipment. Consult your Sherwin-Williams
Representative regarding unique applications.

CAUTIONS:
Thoroughly review product label for safety and cautions prior to using this product. Please direct any questions
or comments to your local Sherwin-Williams facility.

CAUTION!
Causes eye irritation, causes skin irritation, may cause allergic skin reaction, respiratory irritant, dust
may cause eye and respiratory irritation, dust may form an explosive mixture in air. Avoid breathing dust. Avoid
contact with eyes and prolonged or repeated contact with skin. Use protective clothing and NIOSH approved
respirator. Do not use near sparks or open flame or any type of ignition source. Wash thoroughly after handling.
Use only with adequate ventilation.

FIRST AID:
If on SKIN: Wash thoroughly with soap and water.
If in EYES: Flush with water immediately and procure medical attention. The area adjacent to the coating operation
should be properly ventilated. Cure ovens must be exhausted to the outside atmosphere. All dusts are respiratory
irritants, inhalation of the dust should be avoided. To avoid static electricity buildup, properly ground all equipment.
Provide dust collection equipment with adequate explosion venting; dust clouds of any finely divided organic material
can be ignited by open flame or electrical sparks.

DO NOT TAKE INTERNALLY. KEEP OUT OF REACH OF CHILDREN. FOR INDUSTRIAL USE
ONLY. REFER TO MATERIAL SAFETY DATA SHEET FOR ADDITIONAL INFORMATION.


Note:
Product Data Sheets are periodically updated to reflect new information relating to the product. It is important that the
customer obtain the most recent Product Data Sheet for the product being used. The information, rating and opinions
stated above pertain to the material currently offered and represent the results of tests believed to be reliable.
However, due to variations in customer handling and methods of application which are not known or under our
control, The Sherwin-Williams Company cannot make any warranties or guaranties as to the end results.


Double Auto Attendant Waste Container, Concrete Recycling Centers, Concrete Trash Receptacles, Concrete Recycling Waste Receptacles, Trash Receptacles, Metal Trash Receptacles, Steel Trash Receptacles, Weathergard, Polysteel, Streetscape, Aspen
Series, and American Series from your source for material handling equipment.